Products description
The aquabus X4 expansion board for aquaero 5 or aquaero 6 devices provides four aquabus connectors for additional aquabus devices.
Connecting multiple aquabus devices to an aquaero usually means using some aquabus splitter cables - the aquabus X4 provides four dedicated aquabus connectors, reducing the number of splitters needed for complex aquabus setups. Additionally, the aquabus X4 board is not just a splitter: A driver chip on the aquabus X4 provides each of the four aquabus connectors with a "clean" aquabus signal for optimum aquabus performance.
Guidelines and recommendations:
- If used with multiple Calitemp sensors, each Calitemp sensor must be connected to an individual connector of the aquabus X4 board - do not connect two Calitemp sensors to the same connector using splitter cables!
- All other aquabus devices (such as poweradjust, mps, farbwerk, etc.) can be connected to any connector of the aquabus X4 board in any combination, also to ports that are connected to (exactly one) Calitemp sensor. Use aquabus splitters (product codes 53063, 53124 or 53231) to connect multiple devices.
- The aquabus X4 board does not affect the maximum number of aquabus devices to be connected to an aquaero. Refer to the aquaero manual for maximum number of aquabus devices per type.
- Connect a similar number of devices to each of the four aquabus connectors of the aquabus X4 board for optimum performance.
- Do not connect multiple aquabus X4 boards to one aquaero! For additional aquabus connectors, use aquabus splitters (product codes 53063, 53124 or 53231).
- Simultaneous operation of Real Time Clock expansion module and aquabus X4 expansion board is possible. For this purpose, use connection cable 53122 or 53162 and follow the instructions in the manual. Simultaneous (stacked) installation of Real Time Clock module and aquabus X4 expansion board on top of the aquaero board is not possible, the Real Time Clock module has to be mounted separately in this case.
Scope of delivery:
aquabus X4 board
Mounting material
Compatible with:
aquaero 5 XT/PRO/LT, firmware version 2100 or newer, aquasuite 2018-1 or newer
aquaero 6 XT/PRO/LT, firmware version 2100 or newer, aquasuite 2018-1 or newer
If you are currently still using an older version of aquasuite up to version 2017-3, an update must be made to be able to use the article. For this you may have to additionally purchase the update service!
Further information about the update service and the activation of the aquasuite software can be found here.
Connecting multiple aquabus devices to an aquaero usually means using some aquabus splitter cables - the aquabus X4 provides four dedicated aquabus connectors, reducing the number of splitters needed for complex aquabus setups. Additionally, the aquabus X4 board is not just a splitter: A driver chip on the aquabus X4 provides each of the four aquabus connectors with a "clean" aquabus signal for optimum aquabus performance.
Guidelines and recommendations:
- If used with multiple Calitemp sensors, each Calitemp sensor must be connected to an individual connector of the aquabus X4 board - do not connect two Calitemp sensors to the same connector using splitter cables!
- All other aquabus devices (such as poweradjust, mps, farbwerk, etc.) can be connected to any connector of the aquabus X4 board in any combination, also to ports that are connected to (exactly one) Calitemp sensor. Use aquabus splitters (product codes 53063, 53124 or 53231) to connect multiple devices.
- The aquabus X4 board does not affect the maximum number of aquabus devices to be connected to an aquaero. Refer to the aquaero manual for maximum number of aquabus devices per type.
- Connect a similar number of devices to each of the four aquabus connectors of the aquabus X4 board for optimum performance.
- Do not connect multiple aquabus X4 boards to one aquaero! For additional aquabus connectors, use aquabus splitters (product codes 53063, 53124 or 53231).
- Simultaneous operation of Real Time Clock expansion module and aquabus X4 expansion board is possible. For this purpose, use connection cable 53122 or 53162 and follow the instructions in the manual. Simultaneous (stacked) installation of Real Time Clock module and aquabus X4 expansion board on top of the aquaero board is not possible, the Real Time Clock module has to be mounted separately in this case.
Scope of delivery:
aquabus X4 board
Mounting material
Compatible with:
aquaero 5 XT/PRO/LT, firmware version 2100 or newer, aquasuite 2018-1 or newer
aquaero 6 XT/PRO/LT, firmware version 2100 or newer, aquasuite 2018-1 or newer
If you are currently still using an older version of aquasuite up to version 2017-3, an update must be made to be able to use the article. For this you may have to additionally purchase the update service!
Further information about the update service and the activation of the aquasuite software can be found here.
This Product was added to our catalogue on 29/06/2018.
Manufacturer Information
Contact Manufacturer
Aqua Computer GmbH & Co. KG Gelliehäuser Str. 1
37130 Gleichen
Germany
info@aqua-computer.de
Zubehör
A product slider follows - navigate to the individual items using the Tab key.

aquabus cable 4 pins

aquabus cable 4 pins, 15 cm

aquaero 6 LT USB fan controller

aquaero 6 PRO black USB fan controller, graphic LCD

Calitemp digital temperature sensor internal/external thread G1/4 for aquaero 5/6
This product is compatible with:
A product slider follows - navigate to the individual items using the Tab key.

Calitemp digital temperature sensor internal/external thread G1/4 for aquaero 5/6
Customers who bought this product also bought the following products:
A product slider follows - navigate to the individual items using the Tab key.

ULTITUBE 150 reservoir

Fixation ring for ULTITUBE reservoirs

Temperature sensor G1/4 high speed, internal/external thread, rotary, white

Barrow adapter 90°, internal threads G1/4, white

Barrow extension 30 mm, internal/external thread G1/4, white

LED RED ultrabright, 3 mm (ready for connection)
Last viewed:
A product slider follows - navigate to the individual items using the Tab key.