Main page» Monitoring and Controlling» Sensors» Pressure sensor mps pressure Delta 40

Manufacturer

Search

Pressure sensor mps pressure Delta 40

 
 
Pressure sensor mps pressure Delta 40

Zoom Zoom image

60,90 EUR

incl. 19 % VAT excl. shipping costs

Shipping time: In stock, delivery time to DE 1-4 business days  In stock, delivery time to DE 1-4 business days

Product no.: 53133
GTIN/EAN: 4260073415255
Manufacturer part number: 53133
Manufacturer: Aqua Computer
More products of: Aqua Computer

Print datasheet

The pressure sensors of the mps pressure series can be useful for a variety of situations. Foremost they can be used as fill level sensors for virtuelly any type and size of reservoir. In this configuration, the sensor detects the pressure generated by the water column inside the reservoir. The sensor must be installed on the same height or lower than the bottom of the reservoir and one port of the sensor ist connected to one of the bottom inlets of the reservoir. Additionally, either the second port of the sensor has to be connected to a top port of the reservoir or a pressure equalisation membrane has to be installed in a top port of the reservoir. Fittings and membrane are not included in delivery and have to be bought seperately!
Another field of application is differential pressure measurement across filter elements to monitor residues and clogging as a much more precise maintenance indicator than optical inspection. Accordingly, residues and clogging in micro structure coolers can be monitored. A differential pressure measurement between inlet and outlet of a pump can be used for operation monitoring and provide valuable information for hardware testers.
All mps pressure sensors feature an integrated microcontroller with USB and aquabus interface, a programmable alarm output and an external temperature sensor input. For monitoring and configuration, the aquasuite software can be downloaded free of charge. In addition to the USB interface, the 4-pin aquabus interface can be used to directly connect the flow sensor to an aquaero 5 controller (not included in delivery). The alarm output can be configured to be used as a rpm signal to be connected to a fan connector with fault detection (for example motherboard fan headers) or to be used as a switched output for example to connect a LED. Pressure and external temperature sensor input can be configured to raise an alarm. The external temperature sensor input is compatible with all Aqua Computer temperature sensors.

At the moment, four versions of the mps pressure sensor are available that differ in pressure range. Please select the sensor best fitting your requirements:
mps pressure Delta 40 (art. 53133): Differential pressure sensor with two ports, range 0 - 40 mbar (corresponding to a water column of approx. 0 - 40 cm)
mps pressure Delta 100 (art. 53134): Differential pressure sensor with two ports, range 0 - 100 mbar (corresponding to a water column of approx. 0 - 100 cm)
mps pressure Delta 500 (art. 53135): Differential pressure sensor with two ports, range 0 - 500 mbar (corresponding to a water column of approx. 0 - 500 cm)
mps pressure Delta 1000 (art. 53136): Differential pressure sensor with two ports, range 0 - 1000 mbar (corresponding to a water column of approx. 0 - 1000 cm)

Compatibility list for aquabus interface:
aquaero 6 XT / PRO / LT
aquaero 5 XT / PRO / LT

Compatibility list for external temperatue sensor input:
Temperature sensor inline G1/4 (art. 53066)
Temperature sensor inner/outer thread G1/4 (art. 53067)
Temperature sensor G1/4 (art. 53147)
Temperature sensor plug&cool (art. 53025)
Temperature sensor 70 cm (art. 53026)

Scope of delivery:
One flow sensor
One internal USB cable

Technical details:
Dimensions without fittings and without cables: approx. 47 x 34 x 21 mm
Connection thread(s) M5, fittings not included! Distance approx. 12 mm
Mounting threads: 2x M3, distance 24 mm

Notes on the aquasuite software:
When you activate this product you will receive the current version of the aquasuite software including an upgrade service for at least six (6) months. After the expiration of the upgrade service you may use and reinstall the latest version available during the upgrade period without a time limit.
The update service can optionally be extended or renewed at any time for a fee.
Please note that an internet connection is required for the installation and activation of the aquasuite software.
Further information about the update service and the activation of the aquasuite software can be found here.


Aqua Computer GmbH & Co. KG
Gelliehäuser Str. 1
37130 Gleichen
Deutschland

info@aqua-computer.de

Pressure sensor mps pressure Delta 40Pressure sensor mps pressure Delta 40Pressure sensor mps pressure Delta 40Pressure sensor mps pressure Delta 40

Recommended products:

Zubehör

Customers who bought this product also bought the following products:

 

This Product was added to our catalogue on 06/07/2012.